What Are Syringe Filters Used For

Syringe filters are small, single-use devices whose primary job is to remove particulate matter from a sample before it is analyzed or processed. While they are most commonly associated with liquid filtration, certain syringe filters are also suitable for filtering gases or removing aerosols when sampling the gas phase. Their main uses include:

  • Liquid clarification for instrumental analysis. Removing suspended particles from solvents, buffers, biological fluids, and extracts protects sensitive equipment (HPLC/UHPLC columns, mass spectrometers, GC inlets) and improves analytical reproducibility.

  • Sterile filtration. Filters with small pore sizes (commonly 0.22 µm) are used to remove bacteria and larger microbial cells from aqueous solutions, cell culture media or reagents when aseptic handling is required.

  • Sample preparation in environmental and food testing. Water, soil extracts, and food homogenates are routinely syringe-filtered to remove particulates that would otherwise interfere with downstream chemical or microbiological assays.

  • Gas and aerosol particulates removal (selective use). Hydrophobic membranes (for example, PTFE) can be used with syringes to filter particulates or aerosols from gas samples, to protect instrumentation during gaseous sample introduction, or to provide sterile venting (allowing air exchange while excluding particulates and microorganisms). These gas applications are specific and generally involve low-volume, syringe-based sampling rather than continuous gas streams.

  • Pre-filtration and protection of downstream processes. Glass fiber or coarse pre-filters are sometimes used ahead of a fine membrane to extend filter life when samples carry a high particle load.

Types of Syringe Filters and Their Characteristics

Syringe filters are available with a variety of membrane materials, and each type is designed to perform best under certain conditions. The choice of membrane depends largely on the chemical nature of the sample and the purpose of the filtration.

Nylon filters are among the most commonly used because of their broad compatibility with aqueous solutions and many organic solvents. They are hydrophilic, which means they wet easily and allow smooth passage of water-based samples. This makes them suitable for clarifying buffers, biological samples, and many routine laboratory solutions. Nylon also has good mechanical strength, so the membranes resist tearing under moderate pressure.

PTFE filters, made from polytetrafluoroethylene, are valued for their chemical resistance. Unlike nylon, PTFE is hydrophobic, so it repels water but readily passes organic solvents and corrosive solutions. These filters are widely used for aggressive chemicals, strong acids or bases, and in some cases for gas filtration or sterile venting, since the hydrophobic surface blocks aqueous liquids while allowing air to pass.

PES (polyethersulfone) filters are designed for applications where low protein binding is important. They are hydrophilic membranes, allowing fast flow rates, and they minimize the loss of valuable biomolecules during filtration. PES filters are common in pharmaceutical and biotech research, particularly when preparing protein solutions, enzyme mixes, or cell culture media.

PVDF (polyvinylidene fluoride) filters strike a balance between chemical resistance and moderate protein binding. They are durable, can handle many solvents, and are often used in both chemical and biological laboratories. PVDF is a popular choice when working with mixtures of aqueous and organic solvents.

CA (cellulose acetate) filters are preferred when extremely low protein binding is needed. Like PES, they are hydrophilic and offer smooth flow of aqueous samples, but they are especially suitable for sterile filtration of tissue culture media, enzymes, and sensitive biological solutions where sample integrity must be preserved.

For samples that carry a heavy particle load, syringe filters can also be combined with glass fiber pre-filters. These act as a first layer to capture larger debris, protecting the finer membrane beneath and extending its useful life.

How to Choose the Right Syringe Filter

Selecting the right syringe filter is a matter of matching the membrane type, pore size, and filter diameter to the needs of your experiment. The chemical composition of the sample should guide the choice of membrane — for example, hydrophilic membranes such as nylon or PES work well for aqueous solutions, while hydrophobic membranes like PTFE are preferred for organic solvents and gases.

Pore size is another critical factor. Filters with 0.45 μm pores are often used for general clarification of samples, removing larger particulates before analysis. For applications requiring sterile solutions or the removal of bacteria, 0.22 μm filters are the standard choice. If you would like a more detailed comparison of these options, you can refer to our Ultimate Guide to Syringe Filters, which explains the differences between 0.22 and 0.45 micron filters in greater depth.

Finally, filter diameter should be chosen based on the volume of sample to be processed. Smaller filters (such as 13 mm) are suitable for low-volume samples, while larger ones (25 mm or more) are better suited for volumes above 10 mL.

Syringe Filter Quick Selection Guide
Syringe Filter Quick Selection Guide

Click to view original image

How to Use Syringe Filters

Using a syringe filter correctly is essential for maintaining sample integrity and avoiding contamination. The process begins by attaching the filter securely to the end of the syringe, making sure the connection is tight with either a Luer lock or Luer slip fitting. Once the filter is in place, the sample can be drawn into the syringe with care to avoid introducing air bubbles, which may disrupt the filtration process.

Before applying pressure, it is good practice to hold the syringe upright so that the membrane is evenly wetted by the sample. This helps create a consistent flow and reduces the chance of uneven filtration. As the plunger is pressed down gently, the liquid passes through the filter membrane. Many laboratory protocols recommend discarding the first fraction of the filtrate—often about 0.25 to 0.5 mL—to reduce the possibility of contaminants or extractables affecting the results.

During filtration, it is important to pay attention to back pressure. A noticeable increase in resistance usually indicates that the membrane is becoming clogged. Rather than forcing the liquid through, which can damage the filter or compromise the sample, the safer choice is to replace the filter and continue. Once the filtration is complete, both the syringe and the filter should be disposed of according to laboratory safety and waste management procedures, as syringe filters are designed for single use only.

Important Considerations When Using Syringe Filters

Beyond the basic operating steps, successful and reliable filtration depends on several key factors. Paying attention to these considerations will help you protect your sample, your instruments, and the integrity of your results.

1. Filter Selection is Critical for Success The most common source of filtration failure is an incorrect choice of filter. Before you begin, always verify that the filter is appropriate for your application:

  • Chemical Compatibility: Ensure the filter’s membrane material (e.g., PTFE, PVDF, Nylon, PES) is compatible with your sample solvent. Using an incompatible filter can cause it to dissolve, contaminating your sample and potentially damaging your analytical instruments.

  • Pore Size: Select a pore size based on your goal. Use 0.45 µm for general clarification and HPLC particle removal, but choose 0.22 µm when sterilization or the complete removal of bacteria is required.

  • Filter Diameter: Match the filter diameter (e.g., 13 mm, 25 mm, 33 mm) to your sample volume. Using a filter that is too small for the volume will lead to rapid clogging and high back pressure.

2. Understand Your Sample’s Properties Not all samples are created equal. For samples that are difficult to filter:

  • High Viscosity: Viscous liquids require more pressure to filter and will clog membranes more quickly. Consider gently warming the sample (if it is thermally stable) or using a filter with a larger surface area.

  • High Particle Load: For samples with a high concentration of particulates, use a filter with a built-in glass fiber pre-filter. This pre-filter layer traps larger particles, preventing the main membrane from clogging prematurely.

3. Respect Pressure and Volume Limits Every syringe filter has a maximum operating pressure and a recommended sample volume.

  • Do Not Exceed Maximum Pressure: The feeling of high back pressure is a sign that the filter has reached its particle-holding capacity. Applying excessive force can cause the filter housing to burst, resulting in sample loss and a potential safety hazard.

  • Follow Volume Guidelines: Overloading a filter with too much volume is inefficient. It is often faster to use two separate filters for a large volume than to force the entire volume through a single, clogged filter.

4. Minimize Extractables for Sensitive Analyses While discarding the first fraction of filtrate is good practice, for highly sensitive analyses like LC-MS or trace analysis, it is crucial to use filters that are certified as “low-extractable.” These filters are manufactured and tested to ensure they will not leach interfering compounds into your clean sample.

5. Maintain Sterility When Required If your goal is sterile filtration for applications like cell culture, you must use a pre-sterilized, individually packaged syringe filter. Furthermore, the entire process must be performed using aseptic technique in a sterile environment (e.g., a laminar flow hood) to prevent the filtered sample from becoming re-contaminated.

Syringe filters may appear to be simple tools, but their role in protecting samples and ensuring accurate results is critical across many areas of research. By understanding the different membrane options and following good practices during use, researchers can minimize contamination risks and improve the reliability of their experiments. For those seeking dependable laboratory supplies, GenFollower provides high-quality ​​​​PES, Nylon, and CA syringe filters that meet the needs of routine sample preparation and sensitive analytical work alike.

Recent Posts

  • robotic pipetting and robotic tips

Fast Guide to Robotic Pipetting and Robotic Pipette Tips

In today’s automated laboratories, every microliter counts. From high-throughput screening and genomic sequencing to clinical diagnostics and drug discovery, the accuracy of each liquid transfer directly impacts the reliability of results. At the heart [...]

  • 4 Common Laboratory Sterilization Methods

4 Common Laboratory Sterilization Methods

In biological/chemical laboratories, sterilization is a crucial and unavoidable topic. Ensuring every pipette tip, tube and plate in your lab is truly sterile isn’t just good practice—it’s the difference between reliable data and costly [...]